Products Directory   |    Rubber Trade   |    Classifieds   |    E-Rubber Shop   |    E-Rubber Newsletter   |    Rubber Jobs   |    Home

IRD Services   |    Join Free   |    Add Your Company   |    Premium Membership   |    Advertise With Us   |    Discussion Forum

Search:  
   Quick Products:   Adhesives, Auto & Cycle Parts, Rubber Beltings, More...
  Welcome Guest Login
   Forgot Password | Join Free 14 June,2026

Ask Rubber Experts   |   Rubber News   |    Rubber Prices   |    IRD Network Member      Rubber Events

   IndiaRubberDirectory.com > Rubber Trade

Want to Sell
Home New Trade
Trade - Want to Buy
Topic Fluoroquinolone Strip Test Kit 
Name NICOLE 
Company REAGEN 
Address 102 Commerce Dr. Unit 8, Moorestown, NJ 08057  
Phone  
Mobile  
Fax  
Country USA 
Date Created 9/28/2013 2:01:17 PM 
Message Product description
REAGEN™ Fluoroquinolone Strip Test Kit is a qualitative and rapid lateral flow assay designed to detect fluoroquinolone antibiotic residues in raw commingled cow’s milk. This state-of-the-art test uses a broad-spectrum antibody capable of specifically detecting a range of fluoroquinolone residues. This test is designed for point-of-care use or reference lab settings and eliminates the need for a heating block.
The features of the kit are:
 Rapid strip test method – 7 minutes
 Broad-spectrum antibody that requires no heating step
 High sensitivity
 High reproducibility

Mechanism of reaction
The assay uses a competitive colloidal gold based format.The milksample(200μL)is added to a clear plastic reaction vessel,and used to resuspend the lyophilized reagents to a uniform pink color in the bottom of the microtiter wells.The milk is incubated briefly(3 min)to allow the fluoroquinolone antibody on the gold particles to engage with any fluoroquinolone antibiotic residues present in the milk.The test strip is then inserted into the sample well with the arrows pointing downward initiating capillary flow up the strip.Any gold particles that are not complexed with antibiotics present in the milk will bind to the fluoroquinolone antibiotic imprinted at the Test line(T-line),forming a signal(red line)at that position.If the fluoroquinolone antibody on the gold particle has engaged with antibiotic present in the milk sample,the gold particle will flow past the T-line and reach the Control line(C-line).For visual interpretation of the test results,T-line signal intensity that is stronger than the signal at the C-line indicates a negative result.Signal at the T-line which is equal or less intense compared to the C-line indicates the presence of fluoroquinolone antibiotics in the milk.The greater the reduction in signal intensity at the T-line,the greater the concentration of fluoroquinolone antibiotic residues present in the milk.

Sensitivity (detection limit)
Fluoroquinolones
Antibiotic (MRL) Detection limit (μg/L)
Enrofloxacin (100) 1.5-2.5 ppb
Ciprofloxacin(100) 1-2 ppb
Difloxacin 20-30 ppb
Sarafloxacin 20-30 ppb
Norfloxacin 1-2 ppb
Marbofloxacin (75) 4-6 ppb
Danofloxacin (30) 2-3 ppb
Flumequine (50) 4-6 ppb









Kit Contents, Storage and Shelf Life
The REAGEN™ Fluoroquinolone Strip Test Kit has the capacity for 96 (RNS92009-01) or 192 (RNS92009-02) determinations. The shelf life is 24 months when the kit is properly stored.
The positive and negative control vials contain lyophilized raw milk samples, and must be reconstituted with 1 mL of distilled water before use. The reconstituted raw milk controls are stable for 48 hours at 4°C. Additional positive and \ negative control vials are available separately .



RNS92009-01
Kit Contents Amount Storage
Reaction wells 6 x 16 (96 total) 4°C
Test strips 6 x 16 strips (96 total)
Positive control (10 ppb Norfloxacin +/- 0.5 ) 1 vial
Negative control 1 vial
Pipette tips 100 tips RT

RNS92009-02
Kit Contents Amount Storage
Reaction wells 12 x 16 (192 total) 4°C
Test strips 12 x 16 strips (192 total)
Positive control (10 ppb Norfloxacin +/- 0.5 ) 2 vials
Negative control 2 vials
Pipette tips 200 tips RT
A 96-well plastic frame is also provided in each kit to anchor the reaction vessels in place during testing, and can be re-used as required.
Required Materials Not Provided With the Kit
 Timer/Watch
 Additional positive and negative controls
 Polypropylene tubes, clean vials, or small glass test tubes
 Distilled water
 Scissors to cut strip caps
 
 
      
  Rubber Trade

Rubber Product Manufacturers

Get listed in IRD
Premium listing in IRD

 

 

 

 



 

 










New Page 1
    Rubber Articles
   Technical Papers
   Press Releases
   Rubber Articles
   Rubber Statistics
 
 
 
 
 
 
 
 




Contact Us : www.indiarubberdirectory.com C/o Team Web Power, No.52, First Floor, Anna Nagar Plaza, C-47, IInd Avenue,
Anna Nagar, Chennai 600040. India. 
Phone:- +91-44-42170137 Mobile:- +91-9444001705 Email:- [email protected] / [email protected]

|    About Us    |    Vision    |    Disclaimer    |    Privacy Policy     | Sitemap     |    Feedback    |    Contact Us    |    Home    |

Contact Us : www.indiarubberdirectory.com , No.52, First Floor, Anna Nagar Plaza, C-47, IInd Avenue, Anna Nagar, Chennai 600040.Tamilnadu, India.

Phone: +91-44-42170137  Mobile: +91-9444001705  Email:
[email protected]