Products Directory   |    Rubber Trade   |    Classifieds   |    E-Rubber Shop   |    E-Rubber Newsletter   |    Rubber Jobs   |    Home

IRD Services   |    Join Free   |    Add Your Company   |    Premium Membership   |    Advertise With Us   |    Discussion Forum

Search:  
   Quick Products:   Adhesives, Auto & Cycle Parts, Rubber Beltings, More...
  Welcome Guest Login
   Forgot Password | Join Free 13 June,2026

Ask Rubber Experts   |   Rubber News   |    Rubber Prices   |    IRD Network Member      Rubber Events

   IndiaRubberDirectory.com > Rubber Trade

Want to Sell
Home New Trade
Trade - Want to Buy
Topic Aflatoxin M1 Strip Test 
Name NICOLE 
Company REAGEN 
Address 102 Commerce Dr. Unit 8, Moorestown, NJ 08057  
Phone  
Mobile  
Fax  
Country USA 
Date Created 9/28/2013 1:39:42 PM 
Message Product Description
Kit Contents Amount Storage
Reaction wells 6 x 16 (96 total) 4°C
Test Strips 6 x 16 strips (96 total)
Positive Control (0.5 ppb Aflatoxin M1) 1 vial
Negative Control 1 vial
Pipette tips 100 tips RT
REAGEN™ Aflatoxin M1 Strip Test is a qualitative and rapid lateral flow assay designed to detect Aflatoxin M1 residues in raw commingled cow’s milk at 0.5ppb. This immunochromatographic assay eliminates the need for a heating block. This test is designed for field use or reference lab settings.The unique features of the kit are:
 Rapid strip test method – 10 minutes
 High affinity antibody method that requires no heating step
 Works in cold milk
 No sample preparation
 High sensitivity
 High reproducibility
Procedure Overview
The assay uses a competitive colloidal gold based format. The milk sample (200 μL) is added to a clear plastic reaction vessel, and used to resuspend the lyophilized reagents to a uniform pink color in the bottom of the microtiter wells. The milk is incubated briefly (5 min) at room temperature to allow the Aflatoxin M1 binding protein on the gold particles to engage with any Aflatoxin M1 antibiotic present in the milk. The test strip is then inserted into the sample well with the arrows pointing downward initiating capillary flow up the strip. Any gold particles that are not complexed with antibiotics present in the milk will bind to the Aflatoxin M1 antibiotic imprinted at the Test line (T-line), forming a signal (red line) at that position. If the Aflatoxin M1 binding protein on the gold particle has engaged with antibiotic present in the milk sample, the gold particle will flow past the T-line and reach the Control line (C-line). For visual interpretation of the test results, T-line signal intensity that is stronger than the signal at the C-line indicates a negative result. Signal at the T-line which is equal or less intense compared to the C-line indicated the presence of Aflatoxin M1 antibiotics in the milk. The greater the reduction in signal intensity at the T-line, the greater the concentration of Aflatoxin M1 antibiotics present in the milk.

Kit Contents, Storage and Shelf Life
The REAGEN™ Aflatoxin M1 Strip test has the capacity for 96 determinations. The shelf life is 12 months when the kit is properly stored. The positive and negative control vials contain lyophilized raw milk samples, and must be reconstituted with 0.8 mL of distilled water before use. The reconstituted raw milk controls are stable for 48 hours at 4°C. Additional positive and negative control vials are available separately
RNS92008-01

RNS92008-02
Kit Contents Amount Storage
Gold reaction wells 12 x 16 (192 total) 4°C
Test Strips 12 x 16 strips (192 total)
Positive Control (0.5 ppb Aflatoxin M1) 2 vial
Negative Control 2 vial
Pipette tips 200 tips RT
A 96-well plastic frame is also provided in each kit to anchor the reaction vessels in place during testing, and can be re-used as required.

Sensitivity (Detection Limit)
Sample Type Detection Limit (ng/g or ppb)
Raw commingled cow’s milk 0.5

Required Materials Not Provided With the Kit
 Timer
 Additional positive and negative controls
 Polypropylene tubes
 Distilled water
 Scissors to cut strip caps
Optional Materials Not Provided With the Kit
 Detekt RDS-1000 test strip reader
Note: this product was developed using the Detekt RDS-1000 reader, and is highly recommended for optimal performance. For customers already possessing the Detekt RDS-1000 reader, or wishing to use an alternate reader, please contact REAGEN at [email protected] for instructions on how to program the reader for use with this kit.
 
 
      
  Rubber Trade

Rubber Product Manufacturers

Get listed in IRD
Premium listing in IRD

 

 

 

 



 

 










New Page 1
    Rubber Articles
   Technical Papers
   Press Releases
   Rubber Articles
   Rubber Statistics
 
 
 
 
 
 
 
 




Contact Us : www.indiarubberdirectory.com C/o Team Web Power, No.52, First Floor, Anna Nagar Plaza, C-47, IInd Avenue,
Anna Nagar, Chennai 600040. India. 
Phone:- +91-44-42170137 Mobile:- +91-9444001705 Email:- [email protected] / [email protected]

|    About Us    |    Vision    |    Disclaimer    |    Privacy Policy     | Sitemap     |    Feedback    |    Contact Us    |    Home    |

Contact Us : www.indiarubberdirectory.com , No.52, First Floor, Anna Nagar Plaza, C-47, IInd Avenue, Anna Nagar, Chennai 600040.Tamilnadu, India.

Phone: +91-44-42170137  Mobile: +91-9444001705  Email:
[email protected]