Products Directory   |    Rubber Trade   |    Classifieds   |    E-Rubber Shop   |    E-Rubber Newsletter   |    Rubber Jobs   |    Home

IRD Services   |    Join Free   |    Add Your Company   |    Premium Membership   |    Advertise With Us   |    Discussion Forum

Search:  
   Quick Products:   Adhesives, Auto & Cycle Parts, Rubber Beltings, More...
  Welcome Guest Login
   Forgot Password | Join Free 14 June,2026

Ask Rubber Experts   |   Rubber News   |    Rubber Prices   |    IRD Network Member      Rubber Events

   IndiaRubberDirectory.com > Rubber Trade

Want to Sell
Home New Trade
Trade - Want to Buy
Topic Nandrolone ELISA Test Kit 
Name nicole 
Company reagen 
Address 102 Commerce Dr. Unit 8, Moorestown, NJ 08057  
Phone  
Mobile  
Fax  
Country usa 
Date Created 9/28/2013 1:17:09 PM 
Message Product Description
REAGEN™Nandrolone ELISA Test Kit is a competitive enzyme immunoassay for the quantitative analysis of Nandrolone in fish,shrimp, meat and urine.
The unique features of the kit are:
 High recovery (75-105%), rapid (10 - 40 minutes), and cost-effective extraction methods
 High sensitivity (0.015 ng/g or ppb) and low detection limit (0.0075 ng/g or ppb) for meat samples
 High reproducibility
 A quick ELISA assay (less than 2 hours regardless of number of samples)

Procedure Overview
The method is based on a competitive colorimetric ELISA assay. The Nandrolone antibody has been coated in the plate wells. During the analysis, sample is added along with the enzyme-conjugate. If the target is present in the sample, it will compete for the antibody, thereby preventing the HRP from binding to the antibody attached to the well.The resulting color intensity, after addition of substrate, has an inverse relationship with the target concentration in the sample.

Kit Contents, Storage and Shelf Life
The REAGEN™ Nandrolone ELISA Test Kit has the capacity for 96 determinations or testing of 42 samples in duplicate (assuming 12 wells for standards). Return any unused microwells to the foil bag and reseal them with the desiccant provided in the original package. Store the kit at 2-8℃. The shelf life is 12 months when the kit is properly stored.

Kit Contents Amount Storage
Nandrolone-coated Microtiter Plate 1 x 96well Plate (8 wells x 12 strips) 2-8C
Nandrolone Standard : 150 ng/mL 2.0 mL 2-8C
Nandrolone Antibody #1 12 mL
2-8C


2-8C

100X HRP-Conjugated Antibody #2 250 L
Antibody #2 Diluent 20 mL
10X PBS 25 mL
20X Wash Solution 30 mL
Stop Buffer 14 mL
TMB Substrate 10 mL 2-8C
Sample Balance Buffer I
Sample Balance Buffer II
Tissue Clean Up Mix 10 mL
62 g
25 g

If you are not planning to use the kit for over 1 month, store Nandrolone Antibody #1 and 100X HRP Conjugate Antibody #2 at -20°C or in a freezer.

Sensitivity (Detection Limit)

Sample Type Detection Limit (ng/g or ppb)
Meat/Fish/shrimp 0.0075
Urine 0.075

Specificity (Cross-Reactivity)

Analytes Cross-Reactivity (%)
Nandrolone 100
Boldenone 85
Testosterone 81
Mesterolone 50
Stanozolol 30
Trenbolone <0.1

Required Materials Not Provided With the Kit

 Microtiter plate reader (450 nm)
 Incubator
 Tissue Mixer (e.g. Omni TissueMaster Homogenizer)
 Rotary evaporator or nitrogen gas
 Vortex mixer (e.g. Genie Vortex mixer from VWR)
 10, 20, 100 and 1000 µL pipettes
 Multi-channel pipette: 50-300 L (Optional)


Warnings and Precautions

 The standards contain Nandrolone . Handle with particular care.
 Do not use the kit past the expiration date.
 Do not intermix reagents from different kits or lots except for components with the same part No’s within their expiration dates. Make sure that the HRP Conjugate and Diluent are mixed in correct volumes.
 Try to maintain a laboratory temperature of 20°–25°C (68°–77°F). Avoid running assays under or near air vents, as this may cause excessive cooling, heating and/or evaporation. Also, do not run assays in direct sunlight, as this may cause excessive heat and evaporation. Cold bench tops should be avoided by placing several layers of paper towel or some other insulate material under the assay plates during incubation.
 Make sure you are using only distilled or deionized water since water quality is very important.
 When pipetting samples or reagents into an empty microtiter plate, place the pipette tips in the lower corner of the well, making contact with the plastic.
 Incubations of assay plates should be timed as precisely as possible. Be consistent when adding standards to the assay plate. Add your standards first and then your samples.
 Add standards to plate only in the order from low concentration to high concentration, as this will minimize the risk of compromising the standard curve.
 Always refrigerate plates in sealed bags with a desiccant to maintain stability. Prevent condensation from forming on plates by allowing them equilibrate to room temperature (20 – 25°C /68 – 77°F) while in the packaging.
 
 
      
  Rubber Trade

Rubber Product Manufacturers

Get listed in IRD
Premium listing in IRD

 

 

 

 



 

 










New Page 1
    Rubber Articles
   Technical Papers
   Press Releases
   Rubber Articles
   Rubber Statistics
 
 
 
 
 
 
 
 




Contact Us : www.indiarubberdirectory.com C/o Team Web Power, No.52, First Floor, Anna Nagar Plaza, C-47, IInd Avenue,
Anna Nagar, Chennai 600040. India. 
Phone:- +91-44-42170137 Mobile:- +91-9444001705 Email:- [email protected] / [email protected]

|    About Us    |    Vision    |    Disclaimer    |    Privacy Policy     | Sitemap     |    Feedback    |    Contact Us    |    Home    |

Contact Us : www.indiarubberdirectory.com , No.52, First Floor, Anna Nagar Plaza, C-47, IInd Avenue, Anna Nagar, Chennai 600040.Tamilnadu, India.

Phone: +91-44-42170137  Mobile: +91-9444001705  Email:
[email protected]